-40%
DC 300V 100A Volt Current ZVS Power Meter Detector Discharge Battery Monitor New
$ 15.62
- Description
- Size Guide
Description
Product DescriptionDC 300V 100A Volt Current ZVS Power Meter Detector Discharge Battery Monitor New
Specification:
Input/output interface: 100 A Large current copper nose screw
Voltage range: 0.00 V ~ 300 V Resolution precision: 0.05 V
Current range: 0.00 A ~ 100 A Resolution precision: 0.05 A
Capacity range: 0 ~ 999.999 Ah Resolution precision: 0.01 Ah
Power cumulative range: 0 ~ 99999.9 Wh Resolution precision: 0.01 Wh
Power range: 000.00 ~ 2999.99 W Resolution precision : 0.01 W
Impedance range: 1 ~ 999.9 Resolution precision: 0.1
Temperature range: 0 ~ 99 ℃ Resolution precision: 1℃
Timing maximum time: 999H59M59S Resolution precision: 1S
Timing remind Settings: the countdown 24 hours of any value
Small current standby alert threshold parameters: < 2 W / 0.5 H
Small voltage power supply requirements: measuring < 7.8V
low voltage, please supply independent power supply interface
Range of 4 ~ 30V dc power supply voltage to the measurement system
Time to refresh: > 500 ms/time > 500 ms/times
Measurement rate: 0.5 times per second
Over-voltage over-current set the alarm mode: display warning interface
to alert users
Overpressure to remind the set range: 1 ~ 300V
Low pressure remind set range: 0 ~ 149V
Flow to remind the set range: 0.2 ~ 100A
Display type: micro power consumption of LCD module LCM black font
green backlit display in both Chinese and English
Product size: 105 x 81 x 17mm
Since the power flow: < 0.02 A
Working temperature: - 10 ~ + 60 degrees Celsius - 10 ~ + 60 ℃
Working humidity: 10 ~ 80 (dew) undoubtedly 10 ~ 80 (no doubt)
The pressure of work: 80 ~ 106 kpa
Operation method:
Keystrokes using method and the capacity, power, time reset Settings:
1) Reset button long-press all data
(mAh、Wh、00:00:00)
2) Quickly button twice - capacity Reset (mAh)
3) Quickly button three - power reset(Wh)
4) Quickly button four - time reset(00:00:00)
5) Quickly button five - Set up automatic standby
and Discharge the countdown to remind regularly
6)When no load output no-load, quick seven keys,
and for the current zero to zero in the current
environment temperature for accurate calibration,
so more can do more accurate measurement in
small current.
7)Click the switch interface, in the high voltage
low voltage when backlit parameter Settings,
by double Strike and three strikes for parameter
adjustment, the adjustment process long press
is a continuous fast speed value adjustment.
Key functions:
1) Keep Press long time the key: Zero all data(mAh,Wh,00:00:00)
2) Double-click the key: for the Capacity data reset to zero
3) Three-click the key:for the electric quantity data reset to zero
4) Four-click the key: for the time data reset to zero
5) Five-click the key: Auto-Standby Mode & Timer for discharge alert
6) Single-click to change the window, entering the setup window for
high&Low Voltage background light, adjust the parameters by
double-clicking or three-clicking, click-holding for continuous and
quick adjust.
7) Without load,quickly click the key for 7 times, for current data
reset to zero(0.00A).It is for Precise calibration in local circumstance,
so that the small current could be precisely measured.
8) Keep pressing the key when power-off, then power-on, entering
the Background setup window for High&Low Voltage over-load,
single-click or double-click to adjust the parameters, keep press
the key long time to reset to the default setup
(Note: Please don't calibrate the voltage or current if without
standard instruments)
Package Included:
1x DC Current Voltage Measure Module
Note:We have upgraded to the newest version with 3 contacts not 4 contacts . This would be better than old version . If you are not sure how to connect or operate, please contact us to get the instruction .Many thanks .
About Us
We are aiming to bring the best products as well as service to all of the customers . If you have any needs, please don't hesitate to contact us at any time .
If you are unsatisfied with the items received ,please contact us (via eBay Message) first before you operate the return or leave feedback .Many thanks.
Payment
We accept PayPal only.
All PayPal payments must be confirmed (shipping and billing addresses must match).
Payment must be received within 7 business days of auction closing.
We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is the same and correct before you pay.thanks.
Shipping
1,We ship items to your PayPal confirmed address only. Please make sure your address in PayPal is matched with your shipping address on ebay before you pay.
2,We are unable to take any responsibility for wrong address, any custom delay or tax. Because transit time is highly depended and provided by Postal Service.
3.Items will be shipped within the handling time as we promised.
4.The ETA Delivery time depends on destination and other factors.(public holidays., natural disasters, customs issue and other unexpected impact, etc)
Import duties, taxes, and charges are not included in the item price and shipping cost. These charges are the buyer's responsibility.
Please check with your country's customs office to determine what these additional costs will be before prior to bidding or buying.
If you have any request or question about our handling and shipping, please feel free to contact us via eBay message.
In a word, we will do our best to serve you.
Returns
If you are unsatisfied with the items received ,please contact us (via eBay Message) first before you operate the return or leave feedback .
We must go to the extreme length to solve all of the issues in the first time.
If you have not received your products within 30 days from payment, please contact us. We
will track the shipment and get back to you asap. Our goal is
customer satisfaction!
powered by