-40%

Intelligent Electronic Load MAX 10A 150W Battery Discharge Capacity Tester US

$ 18.47

Availability: 100 in stock
  • Manufacturer Part Number: Does not apply
  • Consumption: <1.5A
  • Marque: - Sans marque/Générique -
  • Size:: 149×96×80mm/195×105×135mm(package)
  • Display screen: LCM display
  • .Power Voltage: DC6~12V
  • Item must be returned within: 60 Days
  • select: 15W 150V Electronic Load Resistor
  • Marke: Markenlos
  • Condition: New
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Return shipping will be paid by: Buyer
  • Qty: 1Pc
  • EAN: Does not apply
  • MPN: Does not apply
  • UPC: Does not apply
  • Operating temperature: -10~60℃
  • Numéro de pièce fabricant: Non applicable
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: China
  • Marca: - Senza marca/Generico -
  • Model:: Does not apply

    Description

    Home
    Payment
    Shipping
    About us
    Contact us
    Store Categories
    Store Categories
    Business & Industrial
    Home & Garden
    Health & Beauty
    Electronics
    Sporting Goods
    Other
    Details
    Specifications:
    PowerVoltage:DC6~12V Interface:DC5.0
    Voltage measure range:0~150V Accuracy:0.05V
    Current adjustable range:0~10A Accuracy:0.05A
    Capacity range:0~999.999Ah Accuracy:0.001Ah
    Cumulative range:0~99999.9Wh Accuracy:0.01Wh
    Measure range:0~2999.9W Accuracy:0.01W
    Impedance range:0~999.9Ω Accuracy:0.01Ω
    Temperature range:0~99℃ Accuracy:1℃
    Max timing :999:59:59 Accuracy:1s
    Fan cooling power:<150W
    Fan control threshold:Temp>40℃
    Standby reminder threshold:<2W/0.5h;
    Timing function:>0.5W start timing
    Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB
    Refresh time:>500ms/time
    Measurement rate: 0.5time/s
    Over limit alarm: interface warning and buzzer alarm
    Voltage overrun auto- stops discharge range:0~150V
    Current overrun auto- stops discharge range:0~10A
    Power overrun auto- stops discharge range:0~150W
    Display screen: LCM display
    Size:149×96×80mm/195×105×135mm(package)
    Weight:570g(package)/370g(net weight)
    Consumption:<1.5A
    Operating temp:-10~60℃
    Operating humidity:10~80(No condensation)
    Mode button function description
    :
    1. Click to switch each display interface
    2. The function of the button operation in the 2-4 interface is as follows:
    ①long press all records to clear;
    ②Double-click capacity (Ah) to reset to zero;
    ③three-stroke power (Wh) reset to zero;
    ④four-stroke power (00:00:00) reset to zero;
    ⑤consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.
    3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:
    ①Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;
    ②The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.
    How to use
    :
    1. Input voltage × current ≤ 150W;
    2. Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)
    3. Long press the mode button to clear all data;
    4. Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.
    5. It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge.
    Interface introduction:
    Note: 150V 10A 150W is the test upper limit, output voltage × input current ≤ 150W
    Product List:
    1*Electronic load host
    1*Power Adapter
    1*Instruction manual
    Shipping Policy
    Payment Method
    Returns Policy
    Shipping Policy
    Payment Method
    Returns Policy
    copyright © 2018 datacaciques
    Home
    Payment
    Shipping
    About us
    Contact us
    Home
    Payment
    Shipping
    About us
    Contact us
    Details
    Specifications:
    PowerVoltage:DC6~12V Interface:DC5.0
    Voltage measure range:0~150V Accuracy:0.05V
    Current adjustable range:0~10A Accuracy:0.05A
    Capacity range:0~999.999Ah Accuracy:0.001Ah
    Cumulative range:0~99999.9Wh Accuracy:0.01Wh
    Measure range:0~2999.9W Accuracy:0.01W
    Impedance range:0~999.9Ω Accuracy:0.01Ω
    Temperature range:0~99℃ Accuracy:1℃
    Max timing :999:59:59 Accuracy:1s
    Fan cooling power:<150W
    Fan control threshold:Temp>40℃
    Standby reminder threshold:<2W/0.5h;
    Timing function:>0.5W start timing
    Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB
    Refresh time:>500ms/time
    Measurement rate: 0.5time/s
    Over limit alarm: interface warning and buzzer alarm
    Voltage overrun auto- stops discharge range:0~150V
    Current overrun auto- stops discharge range:0~10A
    Power overrun auto- stops discharge range:0~150W
    Display screen: LCM display
    Size:149×96×80mm/195×105×135mm(package)
    Weight:570g(package)/370g(net weight)
    Consumption:<1.5A
    Operating temp:-10~60℃
    Operating humidity:10~80(No condensation)
    Mode button function description
    :
    1. Click to switch each display interface
    2. The function of the button operation in the 2-4 interface is as follows:
    ①long press all records to clear;
    ②Double-click capacity (Ah) to reset to zero;
    ③three-stroke power (Wh) reset to zero;
    ④four-stroke power (00:00:00) reset to zero;
    ⑤consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.
    3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:
    ①Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;
    ②The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.
    How to use
    :
    1. Input voltage × current ≤ 150W;
    2. Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)
    3. Long press the mode button to clear all data;
    4. Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.
    5. It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge.
    Interface introduction:
    Note: 150V 10A 150W is the test upper limit, output voltage × input current ≤ 150W
    Product List:
    1*Electronic load host
    1*Power Adapter
    1*Instruction manual
    Shipping Policy
    Payment Method
    Returns Policy
    Shipping Policy
    Payment Method
    We accept Paypal ONLY. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.
    Returns Policy
    We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
    If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund to you after the returned item arrived at our warehouse.
    Please include your eBay ID and item number with any email requests.