-40%

Milwaukee MA920B/1 Direct Measurement Food Grade pH Probe

$ 58.07

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • Brand: Milwaukee
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Seller
  • MPN: MA920B

    Description

    DESCRIPTION
    The MA920 probe is a food grade probe for use with the MW101 or MW102 PRO pH meters.
    DESIGN FEATURES
    The Milwaukee food grade probe is specifically designed for the pH analysis of semisolid foods such as processed meats, soft cheeses, soups, sauces, and sushi rice.
    Top features include:
    OPEN JUNCTION
    The open junction design reduces clogging from suspended solids and proteins found in food and dairy products for a more stable pH measurement and reduced maintenance.
    CONICAL GLASS TIP
    The conical shaped tip design allows for penetration into solids, semi solids, and emulsions for the direct measurement of pH in a variety of food products.
    PVDF BODY
    Polyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents used for disinfection in the food sector, including chlorine (bleach).
    USE AND CARE
    pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
    SENSING BULB
    The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
    REFERENCE JUNCTION
    The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
    You can extend the life of your pH electrode in the following ways.
    STORAGE
    The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
    Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.
    The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
    CLEANING
    Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.
    CALIBRATION
    The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO pH meter accurate.
    Also, calibrate after cleaning or a long period of storage.
    SPECIFICATIONS
    pH Range: 0 -12
    Temperature Range: -5 - 40 C / 23 - 104 F
    Body Material: PVDF
    Reference Electrolyte: Viscolene Gel
    Reference Type: Singe, Ag / AgCl
    Reference Junction: Open
    Max Pressure: 0.1 bar
    Tip Shape:  Conic
    Diameter: 0.24 inches
    Body Length / Overall Length: 2.95 / 5.1 inches
    Cable length: Coaxil, 3.3 feet
    Connection: BNC
    Made in ITALY