-40%

Universal Digital Display Meter 0-10V 0-20mA 2-10V 4-20mA Analog Input Meter US

$ 10.55

Availability: 11 in stock
  • Type: Meter
  • Color: Black
  • Features: Display
  • Voltage: DC8~25V
  • Select Type: Standard
  • Current Type: DC
  • Brand: Unbranded
  • Condition: New

    Description

    Store Categories
    Store Categories
    Other
    Product View
    Details
    Standard Edition
    With RS485 version
    With relay output version
    Digital display instrument analog output link
    Mechanical size: 79 × 43 × 25mm;
    Installation opening: 76.5 × 39.5mm.
    1. The meter can be called a universal analog input display meter. It can be matched with various sensors with analog output to display the actual physical quantity. Such as temperature transmitter, frequency converter, motor speed, pressure, liquid level, concentration, etc.
    2. The instrument supports current input or voltage input.
    3. Default adaptation: 0-10V, 2-10V, 0-20mA, 4-20mA. By setting the bias parameter and gain parameter, it can adapt to other inputs in the range of 0-10V, or 0-20mA.
    4. It is displayed as a percentage by default. You can also set your own display range through F0-2 ~ F0-4.
    5. The instrument with 485 interface has already supported the communication between the meters, and it is convenient to realize multiple displays.
    I. Main features:
    1. Model description:standard version: HXDSBOXAH-NR:
    With RS485 version: HXDSBOXA-485:
    With relay output version: HX DS BOXAI-RL
    2. Standard version and version with RS485, rated power supply voltage range: DC6~25V, power consumption: 24V/40mA: with relay output version, rated power supply voltage
    Range: DC8~25V, power consumption: 24V/50mA: power supply anti-reverse connection and surge protection
    3. 1 analog input, voltage type or current type can be selected
    4. Voltage type input impedance: >30kQ, current type input impedance: <250Ω
    5. Rich parameter settings (please see the parameter description), with its own button, easily complete the parameter configuration: 0.56 inch 4-digit digital tube
    6. "With RS485 version", using standard Modbus-RTU protocol, easy to achieve networking: and support networking between tables,
    7. "With relay output version", with 1 normally open relay output, relay load capacity: 3A30Dc/3A250VAC;
    8. Mechanical size: 79×43×25mm: installation opening: 765×395mm.
    II. Indicator light and signal description:
    1. Front panel diagram
    2. Indicator light:
    a. Only "with RS485 version" is useful: R communication receives data indication: T communication sends data indication
    b. Only the "with relay output version" has: S indicator light on when the relay is closed
    3.Port signal description
    Explanation
    PWR
    Connect to the positive pole of the power supply
    (standard version and version with RS485: DC6~30V: with relay output version: DC8~30V)
    GND
    Power and signal ground
    Ai
    Power and signal ground
    mA
    Current-type analog input signal configuration interface, short-circuited with A,
    then configured as current-type input
    With RS485 version
    485-
    RS485 signal is negative
    485+
    RS485 signal is positive
    With relay output version
    KA
    Relay normally open contact output port
    4.Common wiring diagram:
    5. Button and digital tube display state transition diagram:
    Special note: In the third-level menu, click OK to save the modified parameter value and return to the previous menu, the parameter number is automatically increased by one; and click the SET button to directly return to the previous menu without saving the modified parameter value . Long press
    to make the adjustment value change quickly.
    III.Parameter description:
    The parameters are described as follows
    1. F0 Attendant array display
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    FO-0
    Collected value monitoring
    Monitor the percentage of the current analog input value. Range: 0-100.0%
    read-only
    FO-1
    Display value monitoring
    In the display value in "Monitoring Menu" is calculated by F00, F0-2~F04.
    read-only
    FO-2
    Display accuracy
    The number of decimal places displayed in the "Monitor Menu", range: 0-3.
    1
    Read  write
    FO-3
    Show minimum
    In the "monitoring menu", the value corresponding to "acquisition value" is 0%, the range: -1999~9999
    0
    Read  write
    FO-4
    Show maximum
    In the "Monitoring Menu", the value corresponding to the "Acquisition Value" is 100.0%, the range: 19999~9999
    1000
    Read  write
    2. F1 parameter group-analog configuration parameters
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    F1-0
    Input type selection
    0:0~10V or 0~20mA corresponds to 0~100.0%
    0
    Read  write
    F1-1
    Input filter time
    1: 2~10V or 4-20mA corresponds to 0~100.0%, and it is 0 when it is lower than 2V or 4mA.
    0.200
    Read  write
    F1-2
    Input gain
    Analog input filter time, range: 0-10.000S. The greater the filtering time, the stronger the filtering.
    Range: 0~1000.0%.
    100.0
    Read  write
    F1-3
    Input offset
    -99.9~99.9%, with 10V or 20mA as 100.0%.
    0.0
    Read  write
    F1-4
    Keep
    Unused
    0
    Read  write
    F1-5
    Enter the parameter setting selection
    0: Long press SET button for 3s to enter the parameter setting mode: 1: Keep pressing SET button for more than 3s, and
    Press OK to enter parameter setting mode
    0
    Read  write
    The formula of analog input gain and bias is: adjustment result = (acquisition value + offset) × gain
    F2 parameter group relay output dosing (with relay Output version)
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    F2-O
    Relay output status configuration
    When the output conditions are met, the relay output status:
    0: No control (always open) 1: Relay closed 2: Relay open (not satisfied Closed on condition)
    0
    Read  write
    F2-1
    Condition type
    0: greater than comparison value 1, 1: less than comparison value 2.
    2: Greater than comparison value 1 and less than comparison value 2.
    0
    Read  write
    F2-2
    Comparison value 1
    Range: 0-100.0%
    50.0
    Read  write
    F2-3
    Comparison value 2
    Range: 0-100.0%.
    50.0
    Read  write
    F2-4
    Hysteresis interval
    In order to prevent the relay output from operating frequently near the comparison value, hysteresis interval parameters are introduced
    Range: 0.0%~80.0%.
    Read  write
    Examples are given to illustrate the action mechanism of the hysteresis interval: for example, if "F2 condition type" is selected as "0: greater than comparison value 1", "F22 comparison value 1" is set as 50.0%, and "F24 hysteresis interval" uses the default value of 5.0%. When power on, the collected value increases gradually. When it is greater than 50.0% + 5.0% / 2, the output condition is satisfied. If the collected value decreases, it needs to be less than 50.0% - 5.0% / 2 to reach the non output condition.
    F7 communication parameters and software version (communication parameters are "with RS485 version" for use)
    Parameter
    parameter name
    Scope and description
    Defaults
    Read write
    F7-0
    Local address
    Range: 1~247
    1
    Read write
    F7-1
    Baud rate
    0:1200bp;1: 2400bp5;2:480bps:   3: 9600bps
    4:1920bps;5: 38400bps
    3
    Read write
    F7-2
    Data Format
    0:8,1, None (8 data bits, 1 stop bit, no parity)
    1:8,1, Even (8 data bits, 1 stop bit, even parity)
    2:8,1,Odd (8 data bits, 1 stop bit, odd parity
    3:8,2, None (8 data bits, 2 stop bits, no parity)
    0
    Read write
    F7-3
    Response delay
    Communication response delay time 0~500ms
    5
    Read write
    F7-4
    Communication type
    Use above V1.02
    0: The display table is a Modu slave, and the user host can read the collected values of the display table:
    1: The display table is a network slave between the tables, and can receive the display data of the display table set as the master:
    2: The display table is the network host between the tables, and the display value is sent to the slave display table through the broadcast address
    3: The display table is the inter-table networking host, and the display value is sent to the slave by means of address polling
    Display table, address polling range is: 1~F70 value.
    0
    Read write
    F7-5
    Parameter recovery
    Set to 111 to restore the parameters to the factory settings: other values are invalid.
    1313
    read-only
    F7-6
    Model code
    Module model code 0521H
    0.1
    F7-7
    Send interval time
    The interval time for the host to send the data table during master-slave communication. Range: 0.1~100. 0s
    Read write
    F7-8
    Software version number
    Set module software version number, two decimal places. 1.00 corresponds to the software version number is v1.00
    read-only
    Four、Communication protocol and communication method of "with R485 communication version"
    1. The user host accesses the collected value of the display table
    Communication uses standard Modbus-RTU protocol, read with multiple read command 03H. The returned parameter value is the integer displayed by the nixie tube with the decimal point removed. For example, the F0-0 nixie tube display value is 60.0, and the value read by communication is 600. The Modbus register address has a corresponding relationship with the parameter, such as
    The Modbus register address corresponding to F72 is 0702H, that is, 7 in F7-2 is the high 8-bit value, and 2 in F72 is the low 8-bit value.
    For example, read the parameters F0-0 and F0-1 parameter values (the F1 parameter group uses the default parameter settings), the format is as follows:
    host sends a selective dance
    Slave (HXDSB0XAI) response data
    Slave address is F70
    01H
    Slave address ( F7-0)
    01H
    Mbus function number
    03H
    Modbus function number
    03H
    Start address (high byte)
    00H
    Returns the number of bytes (4 bytes)
    04H
    Start address (low byte)
    00H
    High byte of address content
    02H
    Read word count (high byte)
    00H
    low byte of the content of 000 address
    58H
    Read word count (low byte)
    02G
    High byte of 0001H address content
    02H
    CRC (low byte)
    C4H
    Low byte of 0001H address content
    58H
    CRC (high byte)
    OBH
    CRC (low byte)
    7AH
    CRC (high byte)
    C2H
    In the above example, the read f0-0 and f0-1 are both 0258h = 600, that is, the collected value f0-0 is 60.0%; the displayed value f0-0 is 60.0
    2. Network Description:
    Through the inter table networking, the display value of the data collected from the master table can be transmitted to the slave table through RS485. There can be only one master table in a network, and there can be multiple slave tables. In use, only the main table needs to set the corresponding display range, and the slave table does not need to set the display range.
    Shipping Policy
    Payment Method
    Returns Policy
    Shipping Policy
    Payment Method
    Returns Policy
    Home
    Payment
    Shipping
    About us
    Contact us
    Copyright©2018 datacaciques
    Home
    Payment
    Shipping
    About us
    Contact us
    Store Categories
    Store Categories
    Other
    Product View
    Details
    Standard Edition
    With RS485 version
    With relay output version
    Digital display instrument analog output link
    Mechanical size: 79 × 43 × 25mm;
    Installation opening: 76.5 × 39.5mm.
    1. The meter can be called a universal analog input display meter. It can be matched with various sensors with analog output to display the actual physical quantity. Such as temperature transmitter, frequency converter, motor speed, pressure, liquid level, concentration, etc.
    2. The instrument supports current input or voltage input.
    3. Default adaptation: 0-10V, 2-10V, 0-20mA, 4-20mA. By setting the bias parameter and gain parameter, it can adapt to other inputs in the range of 0-10V, or 0-20mA.
    4. It is displayed as a percentage by default. You can also set your own display range through F0-2 ~ F0-4.
    5. The instrument with 485 interface has already supported the communication between the meters, and it is convenient to realize multiple displays.
    I. Main features:
    1. Model description:standard version: HXDSBOXAH-NR:
    With RS485 version: HXDSBOXA-485:
    With relay output version: HX DS BOXAI-RL
    2. Standard version and version with RS485, rated power supply voltage range: DC6~25V, power consumption: 24V/40mA: with relay output version, rated power supply voltage
    Range: DC8~25V, power consumption: 24V/50mA: power supply anti-reverse connection and surge protection
    3. 1 analog input, voltage type or current type can be selected
    4. Voltage type input impedance: >30kQ, current type input impedance: <250Ω
    5. Rich parameter settings (please see the parameter description), with its own button, easily complete the parameter configuration: 0.56 inch 4-digit digital tube
    6. "With RS485 version", using standard Modbus-RTU protocol, easy to achieve networking: and support networking between tables,
    7. "With relay output version", with 1 normally open relay output, relay load capacity: 3A30Dc/3A250VAC;
    8. Mechanical size: 79×43×25mm: installation opening: 765×395mm.
    II. Indicator light and signal description:
    1. Front panel diagram
    2. Indicator light:
    a. Only "with RS485 version" is useful: R communication receives data indication: T communication sends data indication
    b. Only the "with relay output version" has: S indicator light on when the relay is closed
    3.Port signal description
    Explanation
    PWR
    Connect to the positive pole of the power supply
    (standard version and version with RS485: DC6~30V: with relay output version: DC8~30V)
    GND
    Power and signal ground
    Ai
    Power and signal ground
    mA
    Current-type analog input signal configuration interface, short-circuited with A,
    then configured as current-type input
    With RS485 version
    485-
    RS485 signal is negative
    485+
    RS485 signal is positive
    With relay output version
    KA
    Relay normally open contact output port
    4.Common wiring diagram:
    5. Button and digital tube display state transition diagram:
    Special note: In the third-level menu, click OK to save the modified parameter value and return to the previous menu, the parameter number is automatically increased by one; and click the SET button to directly return to the previous menu without saving the modified parameter value . Long press
    to make the adjustment value change quickly.
    III.Parameter description:
    The parameters are described as follows
    1. F0 Attendant array display
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    FO-0
    Collected value monitoring
    Monitor the percentage of the current analog input value. Range: 0-100.0%
    read-only
    FO-1
    Display value monitoring
    In the display value in "Monitoring Menu" is calculated by F00, F0-2~F04.
    read-only
    FO-2
    Display accuracy
    The number of decimal places displayed in the "Monitor Menu", range: 0-3.
    1
    Read  write
    FO-3
    Show minimum
    In the "monitoring menu", the value corresponding to "acquisition value" is 0%, the range: -1999~9999
    0
    Read  write
    FO-4
    Show maximum
    In the "Monitoring Menu", the value corresponding to the "Acquisition Value" is 100.0%, the range: 19999~9999
    1000
    Read  write
    2. F1 parameter group-analog configuration parameters
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    F1-0
    Input type selection
    0:0~10V or 0~20mA corresponds to 0~100.0%
    0
    Read  write
    F1-1
    Input filter time
    1: 2~10V or 4-20mA corresponds to 0~100.0%, and it is 0 when it is lower than 2V or 4mA.
    0.200
    Read  write
    F1-2
    Input gain
    Analog input filter time, range: 0-10.000S. The greater the filtering time, the stronger the filtering.
    Range: 0~1000.0%.
    100.0
    Read  write
    F1-3
    Input offset
    -99.9~99.9%, with 10V or 20mA as 100.0%.
    0.0
    Read  write
    F1-4
    Keep
    Unused
    0
    Read  write
    F1-5
    Enter the parameter setting selection
    0: Long press SET button for 3s to enter the parameter setting mode: 1: Keep pressing SET button for more than 3s, and
    Press OK to enter parameter setting mode
    0
    Read  write
    The formula of analog input gain and bias is: adjustment result = (acquisition value + offset) × gain
    F2 parameter group relay output dosing (with relay Output version)
    Parameter
    parameter name
    Scope and description
    Defaults
    Read  write
    F2-O
    Relay output status configuration
    When the output conditions are met, the relay output status:
    0: No control (always open) 1: Relay closed 2: Relay open (not satisfied Closed on condition)
    0
    Read  write
    F2-1
    Condition type
    0: greater than comparison value 1, 1: less than comparison value 2.
    2: Greater than comparison value 1 and less than comparison value 2.
    0
    Read  write
    F2-2
    Comparison value 1
    Range: 0-100.0%
    50.0
    Read  write
    F2-3
    Comparison value 2
    Range: 0-100.0%.
    50.0
    Read  write
    F2-4
    Hysteresis interval
    In order to prevent the relay output from operating frequently near the comparison value, hysteresis interval parameters are introduced
    Range: 0.0%~80.0%.
    Read  write
    Examples are given to illustrate the action mechanism of the hysteresis interval: for example, if "F2 condition type" is selected as "0: greater than comparison value 1", "F22 comparison value 1" is set as 50.0%, and "F24 hysteresis interval" uses the default value of 5.0%. When power on, the collected value increases gradually. When it is greater than 50.0% + 5.0% / 2, the output condition is satisfied. If the collected value decreases, it needs to be less than 50.0% - 5.0% / 2 to reach the non output condition.
    F7 communication parameters and software version (communication parameters are "with RS485 version" for use)
    Parameter
    parameter name
    Scope and description
    Defaults
    Read write
    F7-0
    Local address
    Range: 1~247
    1
    Read write
    F7-1
    Baud rate
    0:1200bp;1: 2400bp5;2:480bps:   3: 9600bps
    4:1920bps;5: 38400bps
    3
    Read write
    F7-2
    Data Format
    0:8,1, None (8 data bits, 1 stop bit, no parity)
    1:8,1, Even (8 data bits, 1 stop bit, even parity)
    2:8,1,Odd (8 data bits, 1 stop bit, odd parity
    3:8,2, None (8 data bits, 2 stop bits, no parity)
    0
    Read write
    F7-3
    Response delay
    Communication response delay time 0~500ms
    5
    Read write
    F7-4
    Communication type
    Use above V1.02
    0: The display table is a Modu slave, and the user host can read the collected values of the display table:
    1: The display table is a network slave between the tables, and can receive the display data of the display table set as the master:
    2: The display table is the network host between the tables, and the display value is sent to the slave display table through the broadcast address
    3: The display table is the inter-table networking host, and the display value is sent to the slave by means of address polling
    Display table, address polling range is: 1~F70 value.
    0
    Read write
    F7-5
    Parameter recovery
    Set to 111 to restore the parameters to the factory settings: other values are invalid.
    1313
    read-only
    F7-6
    Model code
    Module model code 0521H
    0.1
    F7-7
    Send interval time
    The interval time for the host to send the data table during master-slave communication. Range: 0.1~100. 0s
    Read write
    F7-8
    Software version number
    Set module software version number, two decimal places. 1.00 corresponds to the software version number is v1.00
    read-only
    Four、Communication protocol and communication method of "with R485 communication version"
    1. The user host accesses the collected value of the display table
    Communication uses standard Modbus-RTU protocol, read with multiple read command 03H. The returned parameter value is the integer displayed by the nixie tube with the decimal point removed. For example, the F0-0 nixie tube display value is 60.0, and the value read by communication is 600. The Modbus register address has a corresponding relationship with the parameter, such as
    The Modbus register address corresponding to F72 is 0702H, that is, 7 in F7-2 is the high 8-bit value, and 2 in F72 is the low 8-bit value.
    For example, read the parameters F0-0 and F0-1 parameter values (the F1 parameter group uses the default parameter settings), the format is as follows:
    host sends a selective dance
    Slave (HXDSB0XAI) response data
    Slave address is F70
    01H
    Slave address ( F7-0)
    01H
    Mbus function number
    03H
    Modbus function number
    03H
    Start address (high byte)
    00H
    Returns the number of bytes (4 bytes)
    04H
    Start address (low byte)
    00H
    High byte of address content
    02H
    Read word count (high byte)
    00H
    low byte of the content of 000 address
    58H
    Read word count (low byte)
    02G
    High byte of 0001H address content
    02H
    CRC (low byte)
    C4H
    Low byte of 0001H address content
    58H
    CRC (high byte)
    OBH
    CRC (low byte)
    7AH
    CRC (high byte)
    C2H
    In the above example, the read f0-0 and f0-1 are both 0258h = 600, that is, the collected value f0-0 is 60.0%; the displayed value f0-0 is 60.0
    2. Network Description:
    Through the inter table networking, the display value of the data collected from the master table can be transmitted to the slave table through RS485. There can be only one master table in a network, and there can be multiple slave tables. In use, only the main table needs to set the corresponding display range, and the slave table does not need to set the display range.
    Shipping Policy
    Payment Method
    Returns Policy
    Shipping Policy
    We will arrange shipping for you within 24 Hours after payment cleared except the holidays.
    -We ship items to Worldwide. Thank you!
    -we will ship out the order in 1-2 business days after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.
    Payment Method
    We accept PayPal payment ONLY, and must be received within 5 days from the date of purchase.
    2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.
    3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.
    Returns Policy
    1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
    2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.
    3. Please include your eBay ID and item number with any email requests.